Skip to content
FlawDB
Sign in

CVE-2026-129713

CRITICAL 9.3EPSS 80%

Stack-based buffer overflow in Danfoss AK-SM8xxA unauthenticated CGI handler

Mitigation

  • Vendor workaround: * Follow the
  • instructions provided in the product’s manual, avoiding Internet exposure
  • of all units on public IP
  • * Make sure remote
  • access to the units is possible only through a secure VPN or in general
  • over a protected network
  • * Configure the
  • units to Strict mode, which ensures higher security levels on the product
  • * Recommend using strong passwords

Who should check

  • Anyone running Danfoss AK-SM8xxA <= 5.4.0

Vulnerability facts

Affected
Danfoss AK-SM8xxA <= 5.4.0
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.3 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
1.90% chance of exploitation in 30 days (percentile 80, 2026-11-26)
CWE
CWE-121
Published
Modified

Description

A stack-based buffer overflow in an unauthenticated CGI handler of the Danfoss AK-SM 8xxA Series controller allows remote attackers to send specially crafted HTTP/S POST requests, leading to memory corruption, webserver restart and hypothetically potential arbitrary code execution with webserver privileges. Authentication is not required to exploit this vulnerability.

Affected and fixed versions

Package / productAffectedFixedSource
Danfoss AK-SM8xxA<= 5.4.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2026-129713. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2026-129713.md
Affected: Danfoss AK-SM8xxA <= 5.4.0
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Danfoss AK-SM8xxA: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2026-129713 being exploited?

There is no confirmed exploitation: CVE-2026-129713 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.90% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2026-129713?

Critical: CVSS 9.3 (v4.0, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2026-129713?

Danfoss AK-SM8xxA <= 5.4.0.

Is there a fix for CVE-2026-129713?

No fixed version is listed in the sources yet. Vendor workaround: * Follow the instructions provided in the product’s manual, avoiding Internet exposure of all units on public IP * Make sure remote access to the units is possible only through a secure VPN or in general over a protected network * Configure the units to Strict mode, which ensures higher security levels on the product * Recommend using strong passwords

How do I check if I'm affected by CVE-2026-129713?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

See all
Vulnerabilities, newest first
SeverityIdentifier / vulnerabilityTechnologySignalsAge
CRITICAL 9.9CVE-2026-127057

Exploitation of Weak or Known Passwords in Danfoss AK-SC 355 and AK-SM 800 Series

Danfoss
EPSS 39%
HIGH 8.2CVE-2025-41450

Authentication bypass with privileged access in Danfoss AK-SM 8xxA Series prior to version 4.2

Danfoss
ExploitedPoC
HIGH 8.8CVE-2023-25914

Authneticated Path Traversal in Danfoss AK-SM800A

Danfoss
Exploited
CRITICAL 9.9CVE-2023-25915

Authenticated Remote Command Execution in Danfoss AK-SM800A

Danfoss
Exploited
Sponsors